Model | Value |
---|---|
Model | 24T4 |
Nominal voltage | 23V |
Practical voltage range | 16.5-28.5V |
Rated capacity | 40Ah |
Rated capacity | 100A |
Rated energy | 0.92kWh |
Cell source | Decommissioned battery |
Chemical system of cell | Lithium titanate |
Nominal voltage of cell | 2.3V |
Rated capacity of cell | 40Ah |
Series and shunt forms of cell | 10s1p |
Quality | 23.5±0.2kg |
Discharge interface | M8 |
Charging time | 2h(internal charge control) |
Auxiliary power bus voltage | 27.8V-28.8V |
Charging cut-off condition | Total voltage ≥28.5V/monomer Voltage≥2.9V |
Charge conversion current | 10A |
Total voltage interval | 16.5V-28.8V |
Control charge current | 20A |
Item | Value |
---|---|
Maximum continuous charging current | 20A |
Charging overcurrent protection current value | 300A |
Charging overcurrent protection delay | 5000mS |
Maximum continuous discharge current | 100A |
Discharge overcurrent protection current value | 300A |
Charging overcurrent protection delay | 5000mS |
Charging overcurrent protection delay | 28.5V |
Total voltage overcurrent protection restoration value | 26V |
Charging overcurrent protection value | 25A |
Charging over-temperature protection value | 60℃ |
Charging over-temperature protection release value | 45℃ |
Charging under-temperature protection value | -10℃ |
Charging under-temperature protection release value | -8℃ |
Discharge over-temperature protection value | 60℃ |
Discharge over-temperature protection release value | 55℃ |
Discharge under-temperature protection value | -30℃ |
Discharge under-temperature protection value | -28℃ |
Discharge under-temperature protection value | 30mV |
Allowable balanced minimum monomer voltage | 2.2V |